ZEVERSOLAR Residential Inverter Zeverlution Series | Zeverlution 1000s ~ Zeverlution 3000s

1 Ratings
Type Single Phase Inverter
Power Range 1kW - 3kW
Region China


Model No.
ZEVERLUTION 1000s ZEVERLUTION 1500s ZEVERLUTION 2000s ZEVERLUTION 3000s
Warranty
Product Warranty 5-year Product Warranty on Materials and Workmanship
Input side (DC)
Maximum DC input power for each MPPT (Pmpptmax)
1430W 2140W 2860W 3900W
Absolute maximum DC input voltage (Vmax)
500V 500V 500V 600V
Rated DC input voltage (Vdcr)
360 V 360V 360V 360V
Start-up DC input voltage (Vstart)
90V 90V 90V 150V
Maximum DC input current (Idcmax)
11A 11A 11A 11A
MPPT input DC voltage range
70V ~ 450 V 70V ~ 450 V 70V ~ 450 V 70V ~ 520V
Number of independent MPPT
1 1 1 1
Rated DC input power (Pdcr)
360 V 360V 360V 360V
Output side (AC)
Rated AC power
1000W 1500W 2000 W 3000W
AC voltage range
180 V ~ 280 V 180 V ~ 280 V 180 V ~ 280 V 180 V ~ 280 V
Nominal AC voltage
220V / 230V / 240V 220V / 230V / 240V 220V / 230V / 240V 220V / 230V / 240V
Rated AC grid voltage
220V / 230V / 240V 220V / 230V / 240V 220V / 230V / 240V 220V / 230V / 240V
Maximum AC output current
5.5A 7.5A 10 A 15A
Output frequency range
45 – 55 Hz 45 – 55 Hz 45 – 55 Hz 45 – 55 Hz
Rated output frequency
50/60Hz 50/60Hz 50/60Hz 50/60Hz
Nominal power factor and adjustable range
1/0.8 overexcited to 0.8 underexcited 1/0.8 overexcited to 0.8 underexcited 1/0.8 overexcited to 0.8 underexcited 1/0.8 overexcited to 0.8 underexcited
No. of Feed-in Phase
Single Phase Single Phase Single Phase Single Phase
Maximum efficiency
97 % 97.2% 97.3% 97.5%
Weighted efficiency (EURO/CEC)
96.3% 96.5 % 96.7% 97.0%
General Data
Dimensions (H/W/D)
346 x 346 x 132 mm 346 x 346 x 132 mm 346 x 346 x 132 mm 346 x 346 x 146 mm
Weight
6.5 kg 6.5 kg 6.5 kg 6.8 kg
Power Consumption as night
<1W <1W <1W <1W
Noise Level
<15dB <15dB <15dB <15dB
Operating Temperature -25 °C to +60 °C
Protection Class IP65
Transformer Transformerless
Humidity 0~100%
Interface LCD
Protection Features Input-side disconnection device,Ground fault monitoring/Grid monitoring,DC reverse polarity protection/ AC short circuit current capability,Protection class,All-pole sensistive residual current-monitoring unit
PDF image