SMA SUNNY BOY 3.0 / 4.0 / 5.0 / 6.0

1 Ratings
Type Three-phase
Power Range 3000- 6000 W
Region Australia


Model No.
Sunny Boy 3.0 Sunny Boy 4.0 Sunny Boy 5.0 Sunny Boy 6.0
Warranty
Product Warranty 5 / 10 / 15 years
Input side (DC)
Maximum DC input power for each MPPT (Pmpptmax)
5500 Wp 7500 Wp - 9000 Wp
Absolute maximum DC input voltage (Vmax)
600 V 600 V 600 V 600 V
Rated DC input voltage (Vdcr)
365 V 365 V 365 V 365 V
Start-up DC input voltage (Vstart)
100 V 100 V 125 V 125 V
Maximum DC input current (Idcmax)
15 A 15 A 15 A 15 A
MPPT input DC voltage range
110 V to 500 V 140- 500 V 175 V to 500 V 210- 250 V
Number of independent MPPT
2 2 2 2
Rated DC input power (Pdcr)
365 V 365 V 365 V 365 V
Output side (AC)
Rated AC power
3000 W 4000 W 5000 W 6000 W
AC voltage range
180 V- 280 V 180 V - 280 V 180 V- 280 V 180 V- 280 V
Nominal AC voltage
240 V 240 V 240 V 240 V
Rated AC grid voltage
220 V / 230 V / 240 V 220-240 V 220-240 V 220-240 V
Maximum AC output current
13.1 A / 13.7 A 17.4 A / 18.2 A 22 A / 22.8 A 26.1 A / 26.1 A
Output frequency range
50 Hz/ 60 Hz 55-65 Hz 50- 60 Hz 50- 60 Hz
Rated output frequency
50 Hz 50 Hz 50 Hz 50 Hz
Nominal power factor and adjustable range
0.8 % 0.8 % 0.8 % 0.8 %
No. of Feed-in Phase
1 / 1 1 / 1 1 / 1 1 / 1
Maximum efficiency
97.0% 97.0% 97.0% 97.0 %
Weighted efficiency (EURO/CEC)
96.4% 96.5% 96.5% 96.6 %
General Data
Dimensions (H/W/D)
435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches)
Weight
17.5 kg 17.5 kg 17.5 kg 17.5 kg
Power Consumption as night
5.0 W 5.0 W 1W 1W
Noise Level
25 dB(A) 25 dB(A) 25 dB(A) 25 dB(A)
Operating Temperature ‒25°C to +60°C (‒13°F to +140°F)
Protection Class IP65
Transformer Transformerless
Humidity 100 %
Interface WLAN / Ethernet / RS485
Protection Features Input-side disconnection point,Ground fault monitoring / grid monitoring,DC reverse polarity protection / AC short circuit current capability / galvanically isolated,All-pole-sensitive residual-current monitoring unit,Protection class (as per IEC 61140) / overvoltage category (according to IEC 60664-1)
PDF image