SMA SUNNY BOY 1.5 / 2.5

1 Ratings
Type Three-phase
Power Range 1500 W-2500 W
Region Australia


Model No.
Sunny Boy 1.5 Sunny Boy 2.5
Warranty
Product Warranty 5 / 10 / 15 years
Input side (DC)
Maximum DC input power for each MPPT (Pmpptmax)
3000 Wp 5000 Wp
Absolute maximum DC input voltage (Vmax)
600 V 600 V
Rated DC input voltage (Vdcr)
360 V 360 V
Start-up DC input voltage (Vstart)
50 V 80 V
Maximum DC input current (Idcmax)
10 A 10 A
MPPT input DC voltage range
- 260 V to 500 V
Number of independent MPPT
1 / 1 1 / 1
Rated DC input power (Pdcr)
360 V 360 V
Output side (AC)
Rated AC power
1500 W 2500 W
AC voltage range
180 V - 280 V 180 V - 280 V
Nominal AC voltage
240 V 240 V
Rated AC grid voltage
220 V / 230 V / 240 V 220 V / 230 V / 240 V
Maximum AC output current
6.5 A / 7 A 11 A / 11 A
Output frequency range
50 Hz, 60 Hz / −5 Hz to +5 Hz 50 Hz, 60 Hz / −5 Hz to +5 Hz
Rated output frequency
50 Hz 50 Hz
Nominal power factor and adjustable range
0.8 % 0.8 %
No. of Feed-in Phase
1 / 1 1 / 1
Maximum efficiency
97.2 % 97.2 %
Weighted efficiency (EURO/CEC)
96.1 % 96.7 %
General Data
Dimensions (H/W/D)
460 / 357 / 122 mm (18.1 / 14.1 / 4.8 inches) 460 / 357 / 122 mm (18.1 / 14.1 / 4.8 inches)
Weight
9.2 kg (20.3 lbs) 9.2 kg (20.3 lbs)
Power Consumption as night
1W < 1W
Noise Level
< 25 dBA < 25 dBA
Operating Temperature −40 °C to +60 °C (−40 °F to +140 °F)
Protection Class IP65
Transformer Transformerless
Humidity 100 %
Interface WLAN / Ethernet
Protection Features DC side disconnection point,Ground fault monitoring / grid monitoring,DC reverse polarity protection / AC short circuit current capability / galvanically isolated,All-pole-sensitive residual-current monitoring unit,Protection class (according to IEC 61140) / surge category (according to IEC 60664-1),Reverse current protection
PDF image